A lot of times, it is required that we do a clean reset/format on the GS sensors or we need to allow the sensor to track a new almanac. Most Leica GS's have two buttons (Button A and B) and when they are pressed simultaneously here's a list of their functionalities:
1 second: |
ME (Measurement Engine initialization) |
3 seconds: |
Formatting SD card |
10 seconds: |
Format GS System Ram |
15 seconds: |
Format GS Windows CE registry |